DCS HD30 Manual do Utilizador Página 26

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 25
24
INSTALLATION INSTRUCTIONS
Remote blower electrical connection
Remove the cover from the remote blower, then remove the wiring box cover.
Pull the electrical wiring through the hole in the blower base and secure it
according to local codes using a suitable UL listed strain relief or conduit fitting
(not included).
Connect the N (neutral) wire to the white wire in the wiring box with twist-on
connector Fig.28.
Connect the L1 (live) wire to the black wire in the wiring box with twist-on
connector Fig.28.
Connect the green power supply ground wire to the green ground screw.
Attention – verify that the main filter, flap and wiring box cover are positioned
correctly with wiring clearance.
Replace the wiring box cover and screws taking care not to pinch the wiring
under the wiring box cover.
Reinstall the remote blower cover.
Ground screws
GREEN -YELLOW
WHITE
BLACK
Motor wiring
Twist-on connectors
Downdraft wiring
GND (ground)
N (neutral)
L1 (live)
Fig.28